Comminution experts

 

Home / Up  

Separator data Metal recycling Mineral sorting Separation examples

 

 


Optical separation unit can be supplied in different configurations and sizes depending on a customer needs and process requirements. Table below shows the standard separator sizes indicating the most important operating parameters. Other sizes are available for tailored applications


 

System size

OSX-600

OSX-1000

OSX-1500

Transport belt width [mm]

600

1000

1500

Belt maximal velocity [m/s]

3

3

3

Image identification

Analogue or Digital frame grabbing

Digital frame grabbing

Digital frame grabbing

Scanning principle

Progressive scan

Camera type

CCD

Identification function

Color, size, shape, structure, texture

Rejection mechanism

Air nozzles for particles below 100 mm

Pneumatic flaps for particles over 100 mm

Minimal particle size [mm]

10

15

20

Maximal capacity based on rock particles of 50 mm size [t/h]

10

30

60

 


Separation capacity of the system very much depends on the material properties. Capacity shown in the table is given for rock particles having 2500 kg/m3 specific gravity and  medium size of 50 mm. 


For more details please contact our technical department:


 

 

Home ] Up ]
Last modified: 11/13/09